Model D-50
Part Number 50029-80
Electrical Specifications
| Voltage | 6 VDC |
| Coil Resistance | 1.42 |
| Power | 25 Watts |
| Duty Cycle | Intermittent |
| On Time | 25% - 3 minutes on max. |
| Duty Cycle/Power Note | |
| Dielectric Strength | 500 VRMS for 1 minute |
| Insulation Class | Class A Rating - 105?C (221?F) standard Class B Rating - 130?C (266?F) optional |
| Standard Coil Treatment | Tape Wrapped |
| Optional Coil Treatment | |
| Termination | Wire leads (standard) |
Mechanical Specifications
| Length | 1.625 |
| Width (Diameter) | 1.562 |
| Height | 1.828 |
| Plunger Diameter | 0.500 |
| Plunger Guide Material | Plastic |
| Life Expectancy | 10^7 Cycles Under Optimum Load Conditions |
| Operation | Pull |
| Weight | Plunger - 1.27 oz. Total - 12 oz. |
Performance Specifications
| Maximum Stroke | 0.850 |
| Stroke (in) | Force (oz) |
| 0.000" | 183 |
| 0.125" | 128 |
| 0.250" | 65 |
| 0.375" | 35 |
| 0.500" | 21 |
| 0.625" | 12 |
| 0.750" | 9 |
| 0.875" | 0 |
| 1.000" | 0 |
Agency Approvals
| UL | UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130 |