Deltrol Controls
 
414.671.6800
HomeAbout UsSales RepsDistributor LocatorCareersLatest NewsContact UsSitemap
A Leader in the Design & Manufacture of Electro-Mechanical Products

Solenoid Model D30-ML

Electrical Specifications for Solenoid Model D30-ML

Insulation Class Class F (155º C)
Standard Coil Treatment Encapsulated
Optional Coil Treatment Tape Wrapped
Termination Wire leads 18 AWG (standard)
Dielectric Strength 30 Volts and Under: 500 VRMS
Over 30 Volts: 100 VRMS plus 2X rated voltage for 1 minute

Solenoid Model D30-ML Mechanical Specs

Length 2.011
Width (Diameter) 1.000
Height 1.218
Plunger Diameter 0.4375
Plunger Guide Material Plastic
Life Expectancy 10^6 Under Optimal Load Conditions
Weight Plunger - 1.2 oz.
Total - 6.3 oz.

Agency Approvals

UL UL File No. E74443 For Insulation Systems
S105, S130, S130D, S130D1, S155D
Part No. Voltage Duty Cycle Power Resistance (ohms) Operation Normally Stocked Typical Force (oz), 100% Voltage,
77° F, @
0.000" 0.125" 0.250" 0.500" 0.750"
53803-86 6 VDC Intermittent 21 Watts 1.71 Pull Yes 96 65 46 19.7 7.7
53806-87 12 VDC 6.86 Pull Yes
53803-88 24 VDC 27.43 Pull Yes
53803-92 6 VDC Pulse 85 Watts 0.42 Pull No 96 172 152 99 31
53803-93 12 VDC 1.69 Pull No
53803-94 24 VDC 6.78 Pull No