| Insulation Class | Class F (155º C) |
| Standard Coil Treatment | Encapsulated |
| Optional Coil Treatment | Tape Wrapped |
| Termination | Wire leads 18 AWG (standard) |
| Dielectric Strength | 30 Volts and Under: 500 VRMS Over 30 Volts: 100 VRMS plus 2X rated voltage for 1 minute |
| Length | 2.011 |
| Width (Diameter) | 1.000 |
| Height | 1.218 |
| Plunger Diameter | 0.4375 |
| Plunger Guide Material | Plastic |
| Life Expectancy | 10^6 Under Optimal Load Conditions |
| Weight | Plunger - 1.2 oz. Total - 6.3 oz. |
| UL | UL File No. E74443 For Insulation Systems S105, S130, S130D, S130D1, S155D |
| Part No. | Voltage | Duty Cycle | Power | Resistance (ohms) | Operation | Normally Stocked | Typical Force (oz), 100% Voltage, 77° F, @ |
||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.000" | 0.125" | 0.250" | 0.500" | 0.750" | |||||||
| 53803-86 | 6 VDC | Intermittent | 21 Watts | 1.71 | Pull | Yes | 96 | 65 | 46 | 19.7 | 7.7 |
| 53806-87 | 12 VDC | 6.86 | Pull | Yes | |||||||
| 53803-88 | 24 VDC | 27.43 | Pull | Yes | |||||||
| 53803-92 | 6 VDC | Pulse | 85 Watts | 0.42 | Pull | No | 96 | 172 | 152 | 99 | 31 |
| 53803-93 | 12 VDC | 1.69 | Pull | No | |||||||
| 53803-94 | 24 VDC | 6.78 | Pull | No | |||||||