| Insulation Class | Class A Rating - 105ºC (221ºF) standard Class B Rating - 130ºC (266ºF) optional |
| Standard Coil Treatment | Tape Wrapped |
| Optional Coil Treatment | |
| Termination | Wire leads (standard) |
| Dielectric Strength | 30 Volts and Under: 500 VRMS Over 30 Volts: 100 VRMS plus 2X rated voltage for 1 minute |
| Length | 2.625 |
| Width (Diameter) | 1.562 |
| Height | 1.828 |
| Plunger Diameter | 0.500 |
| Plunger Guide Material | Plastic |
| Life Expectancy | 10^7 Cycles Under Optimum Load Conditions |
| Weight | Plunger - 1.92 oz. Total - 19 oz. |
| UL | UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130 |
| Part No. | Voltage | Duty Cycle | Power | Resistance (ohms) | Operation | Normally Stocked | Typical Force (oz), 100% Voltage, 77° F, @ |
||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 0.000" | 0.125" | 0.250" | 0.500" | 0.750" | |||||||
| 50046-80 | 6 VDC | Continuous | 13 Watts | 2.75 | Pull | No | 150 | 79 | 62 | 30 | 15 |
| 50046-81 | 12 VDC | 11 | Pull | Yes | |||||||
| 50046-83 | 24 VDC | 44.3 | Pull | Yes | |||||||
| 50046-93 | 110 VDC | 940 | Pull | Yes | |||||||
| 50031-80 | 6 VDC | Intermittent | 48 Watts | 0.75 | Pull | No | 211 | 130 | 112 | 82 | 50 |
| 50031-81 | 12 VDC | 3.0 | Pull | Yes | |||||||
| 50031-83 | 24 VDC | 12.0 | Pull | Yes | |||||||
| 50031-93 | 110 VDC | 254 | Pull | Yes | |||||||
| 53714-81 | 12 VDC | Pulse | 130 Watts | 1.1 | Pull | No | 247 | 180 | 165 | 135 | 100 |
| 53714-83 | 24 VDC | 4.5 | Pull | No | |||||||
| 53714-93 | 110 VDC | 92 | Pull | No | |||||||