Solenoid Model D-70

Electrical Specifications for Solenoid Model D-70

Insulation Class Class A Rating - 105ºC (221ºF) standard
Class B Rating - 130ºC (266ºF) optional
Standard Coil Treatment Tape Wrapped
Optional Coil Treatment
Termination Wire leads (standard)
Dielectric Strength 30 Volts and Under: 500 VRMS
Over 30 Volts: 100 VRMS plus 2X rated voltage for 1 minute

Solenoid Model D-70 Mechanical Specs

Length 2.625
Width (Diameter) 1.562
Height 1.828
Plunger Diameter 0.500
Plunger Guide Material Plastic
Life Expectancy 10^7 Cycles Under Optimum Load Conditions
Weight Plunger - 1.92 oz.
Total - 19 oz.

Agency Approvals

UL UL File No. E57982 For Continuous Duty
UL File No. E74443 For Insulation Systems
S105, S130
Part No. Voltage Duty Cycle Power Resistance (ohms) Operation Normally Stocked Typical Force (oz), 100% Voltage,
77° F, @
0.000" 0.125" 0.250" 0.500" 0.750"
50046-80 6 VDC Continuous 13 Watts 2.75 Pull No 150 79 62 30 15
50046-81 12 VDC 11 Pull Yes
50046-83 24 VDC 44.3 Pull Yes
50046-93 110 VDC 940 Pull Yes
50031-80 6 VDC Intermittent 48 Watts 0.75 Pull No 211 130 112 82 50
50031-81 12 VDC 3.0 Pull Yes
50031-83 24 VDC 12.0 Pull Yes
50031-93 110 VDC 254 Pull Yes
53714-81 12 VDC Pulse 130 Watts 1.1 Pull No 247 180 165 135 100
53714-83 24 VDC 4.5 Pull No
53714-93 110 VDC 92 Pull No