Solenoid Model D-22

Electrical Specifications

Insulation Class Class A Rating - 105?C (221?F) standard
Standard Coil Treatment Encapsulated
Optional Coil Treatment Tape Wrapped
Termination .110" quick connect terminals (standard)
Wire leads optional with tape wrapped coil
Dielectric Strength 30 Volts and Under: 500 VRMS
Over 30 Volts: 100 VRMS plus 2X rated voltage for 1 minute

Mechanical Specifications

Length 1.130
Width (Diameter) 0.750
Height 0.750
Plunger Diameter 0.250
Plunger Guide Material Plastic
Life Expectancy 10^7 Cycles Under Optimum Load Conditions
Weight Plunger - 0.25 oz.
Total - 1.5 oz.

Agency Approvals

UL UL File No. E57982 For Continuous Duty
UL File No. E74443 For Insulation Systems
S105
Part No. Voltage Duty Cycle Power Resistance (ohms) Operation Normally Stocked Typical Force (oz), 100% Voltage,
77° F, @
0.000" 0.125" 0.250" 0.500" 0.750"
53724-80 6 VAC Continuous 6.5 VA 2.75 Pull No 31 3.5 2.4 1 0
53724-81 12 VAC 10.9 Pull No
53724-82 24 VAC 43.4 Pull No
53724-84 120 VAC 1090 Pull No
53724-85 240 VAC 4300 Pull No
53724-86 6 VAC Intermittent 8.5 VA 1.7 Pull No 53 5.2 3.3 1.5 0
53724-87 12 VAC 7.0 Pull No
53724-88 24 VAC 27.4 Pull No
53724-90 120 VAC 724 Pull No
53724-91 240 VAC 2880 Pull No
53724-92 6 VAC Pulse 60 VA 0.420 Pull No 73 19 14 7 0
53724-93 12 VAC 1.7 Pull No
53724-94 24 VAC 27.4 Pull No
53724-96 120 VAC 173 Pull No
53724-97 240 VAC 724 Pull No
53723-80 6 VDC Continuous 4.2 Watts 8.7 Pull No 30 4 1.8 0 0
53723-81 12 VDC 35.0 Pull Yes
53723-82 24 VDC 141 Pull Yes
53723-84 110 VDC 2880 Pull No
53723-86 6 VDC Intermittent 9.6 Watts 3.8 Pull No 38 10 4 0 0
53723-87 12 VDC 14.8 Pull No
53723-88 24 VDC 60 Pull No
53723-90 110 VDC 1274 Pull No
53723-92 6 VDC Pulse 40 Watts 0.91 Pull No 49 27 15 0 0
53723-93 12 VDC 3.8 Pull No
53723-94 24 VDC 14.8 Pull No
53723-96 110 VDC 302 Pull No